ICNIRP exposure limits: the reference levels explained

Last reviewed: 1 November 2026

The short answer: ICNIRP — the International Commission on Non-Ionizing Radiation Protection — is an independent scientific body whose exposure guidelines are adopted, directly or with local changes, by most national regulators, including across the EU. Its limits are split across two current documents: the 2010 guidelines for low-frequency fields (1 Hz–100 kHz), where the power-frequency (50/60 Hz) general-public reference level for magnetic fields is 200 µT, and the 2020 guidelines for radiofrequency fields (100 kHz–300 GHz — the band that carries mobile phones, WiFi, smart meters and 5G), where the whole-body public reference level for power density is 10 W/m² above 2 GHz and frequency-dependent (f/200 W/m²) between 400 MHz and 2 GHz — about 2 W/m² at 400 MHz and roughly 4.5 W/m² at 900 MHz (ICNIRP, 2010, Health Physics 99(6): 818–836; ICNIRP, 2020, Health Physics 118(5): 483–524, Table 5). Typical home backgrounds sit around 0.01–0.3 µT and everyday RF at normal use distances orders of magnitude below these levels (WHO, Environmental Health Criteria 238, 2007). This page consolidates both documents in one place: what each covers, how the limits are built, the published reference levels, and what they are — and are not — meant to protect against.

What ICNIRP is and which guidelines are in force

ICNIRP publishes exposure guidelines built from the established scientific evidence; regulators adopt them directly or with local changes. Two documents are in force today, and they are not competing revisions of the same limits — they divide the spectrum between them, so which set applies depends on the frequency of the field, not on which document is newer:

ICNIRP 2010 ICNIRP 2020
Frequency scope 1 Hz – 100 kHz (low frequency) 100 kHz – 300 GHz (radiofrequency)
Typical sources wiring, appliances, power lines, induction heaters mobile phones, WiFi, smart meters, 5G
Effect the limits protect against electrical stimulation of nerve and muscle by induced internal fields tissue heating (whole-body and local)
Basic-restriction quantity internal induced electric field whole-body and local SAR to 6 GHz, absorbed power density above
Status in force below 100 kHz current RF guidance; replaced the 1998 RF guidelines and the 100 kHz–10 MHz rows of 2010
The division of the spectrum between the two current ICNIRP documents (ICNIRP, 2010; ICNIRP, 2020). Neither supersedes the other across the whole spectrum; at the boundary the 2020 document absorbs only the 100 kHz–10 MHz slice of the 2010 tables.

How the limits are built: basic restrictions and reference levels

Both documents define two layers. A basic restriction limits a quantity inside the body: for low frequencies, the internal electric field induced in nerve tissue, because above certain thresholds induced fields can stimulate nerve and muscle (ICNIRP, 2010); for radiofrequencies, quantities tied to heating — whole-body and local specific absorption rate (SAR) up to 6 GHz, absorbed power density in the skin above, because at those millimetre-wave frequencies heating becomes superficial (ICNIRP, 2020). A reference level is a practical external field strength, chosen so that a person at or below it will stay within the basic restrictions under worst-case assumptions — meaning the reference levels deliberately include a margin, and a field above a reference level does not automatically mean the internal restriction is exceeded (ICNIRP, 2010; ICNIRP, 2020).

The low-frequency limits (ICNIRP 2010: 1 Hz–100 kHz)

The magnetic-field (flux density, B) reference levels for the general public and for workers, reproduced from ICNIRP's Tables 3 and 4 (ICNIRP, 2010); f is the frequency in hertz:

Frequency range Public B-field reference level Occupational B-field reference level
1–8 Hz 4 × 10⁴ / f² µT 2 × 10⁵ / f² µT
8–25 Hz 5 × 10³ / f µT 2.5 × 10⁴ / f µT
25–400 Hz (public) / 25–300 Hz (occupational) 200 µT 1,000 µT
400 Hz–3 kHz (public) / 300 Hz–3 kHz (occupational) 8 × 10⁴ / f µT 3 × 10⁵ / f µT
3 kHz–10 MHz 27 µT 100 µT
Magnetic-field reference levels from ICNIRP (2010), Tables 3 and 4 (unperturbed rms values). The published tables run to 10 MHz; the guidelines' scope is 1 Hz–100 kHz, and above 100 kHz the 2020 radiofrequency guidelines take over (ICNIRP, 2020).

At 50/60 Hz — the frequency of the electricity grid — the public level is therefore 200 µT and the occupational level 1,000 µT. For electric fields, the published general-public reference level at 50/60 Hz is 5 kV/m, two times below the occupational 10 kV/m (ICNIRP, 2010, Tables 3 and 4). For scale, typical home backgrounds sit around 0.01–0.3 µT (WHO, Environmental Health Criteria 238, 2007), so the public level is roughly a thousand times the background — see the per-source comparisons on pages like power lines and household appliances.

What the 2010 limits protect against

These limits are set against established acute effects: electrical stimulation of nerves and muscle by the fields induced inside the body. Below the reference levels, the induced internal fields stay well under stimulation thresholds for even the most sensitive people, including with the margin ICNIRP applies for the general public (ICNIRP, 2010). What the 2010 guidelines do not do is set a separate numerical limit for possible long-term effects: the epidemiological observation that childhood-leukaemia risk is statistically associated with long-term average magnetic fields above roughly 0.3–0.4 µT is classified as a hazard by IARC (IARC Monographs Vol. 80, 2002), but no mechanism is established and the 2010 guidelines state that the underlying evidence is not sufficient to derive quantitative limits from it (WHO, Environmental Health Criteria 238, 2007; ICNIRP, 2010). That is why the 200 µT public reference level and the 0.3–0.4 µT epidemiology band differ by three orders of magnitude — they answer different questions.

The radiofrequency limits (ICNIRP 2020: 100 kHz–300 GHz)

The 2020 basic restrictions are set against the established adverse effect of RF at guideline frequencies — heating — via a whole-body core-temperature threshold and local-temperature thresholds for skin and tissue (ICNIRP, 2020):

The whole-body reference levels for the general public, reproduced from ICNIRP's Table 5 (values also shown for workers; f_M is frequency in MHz) (ICNIRP, 2020):

Frequency range Public — E-field (V/m) Public — power density (W/m²) Workers — power density (W/m²)
0.1–30 MHz 300 / f_M^0.7 — —
30–400 MHz 27.7 2 10
400–2,000 MHz 1.375 √f_M f_M / 200 f_M / 40
2–300 GHz — 10 50
Whole-body (30-minute averaged) reference levels, condensed from ICNIRP (2020), Table 5 — incident E-field strength and incident power density. In the 0.1–30 MHz band ICNIRP publishes no power density value ("not applicable"): compliance there is assessed on the E- and H-field strengths (public H-field: 2.2 / f_M A/m; the workers' column values are 660 / f_M^0.7 V/m and 4.9 / f_M A/m). See the source table for the H-field column and near-field compliance rules.

From 2 GHz up the guidelines additionally publish local reference levels averaged over 6 minutes: 40 W/m² for the public at 2–6 GHz, assessed as the peak spatial average over the projected whole-body area; above 6 GHz, an incident-power-density level averaged over any 4 cm² of body area that falls from about that level to 20 W/m² at 300 GHz (public); and above 30 GHz, twice those values allowed when averaged over any 1 cm² (ICNIRP, 2020, Table 6). These local levels sit above the whole-body 10 W/m² figure — a phone at your ear is assessed against the local and SAR restrictions, not against whole-body values alone.

What changed from the previous (1998) RF guidelines

How this site uses the ICNIRP limits

Frequently asked questions

What does ICNIRP mean?

ICNIRP stands for the International Commission on Non-Ionizing Radiation Protection, the independent scientific body whose exposure guidelines are adopted, directly or with local changes, by most national regulators, including across the EU (ICNIRP, 2010).

What are the ICNIRP reference levels?

The practical external field strengths ICNIRP publishes as the compliance check for its basic restrictions (the limits on quantities inside the body). Today they come from two documents — the 2010 guidelines for 1 Hz–100 kHz (200 µT public at power frequency) and the 2020 guidelines for 100 kHz–300 GHz (10 W/m² public above 2 GHz) — both reproduced with their published tables on this page.

Are the 2010 or the 2020 guidelines current?

Both are in force, over different frequency ranges: the 2010 guidelines below 100 kHz, the 2020 guidelines from 100 kHz to 300 GHz. Neither supersedes the other across the whole spectrum — see the table above for the split and the boundary detail at 100 kHz–10 MHz.

Sources

Every limit and claim on this page carries its dated source:

  1. ICNIRP (2010), "Guidelines for limiting exposure to time-varying electric and magnetic fields (1 Hz to 100 kHz)", Health Physics 99(6): 818–836 (doi: 10.1097/HP.0b013e3181f06c86). All low-frequency reference levels and scope statements on this page are from this document.
  2. ICNIRP (2020), "Guidelines for limiting exposure to electromagnetic fields (100 kHz to 300 GHz)", Health Physics 118(5): 483–524 (doi: 10.1097/HP.0000000000001210). All radiofrequency reference levels, basic restrictions and change statements on this page are from this document (Tables 5 and 6 and Appendix A).
  3. WHO (2007), "Extremely low frequency fields", Environmental Health Criteria 238, World Health Organization — home background levels and the long-term-effect context.
  4. IARC (2002), "Non-ionizing radiation, Part 1: static and extremely low-frequency (ELF) electric and magnetic fields", IARC Monographs, Vol. 80 — the Group 2B classification discussed above.
  5. FCC (1997), "Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields", OET Bulletin 65, Edition 97-01 — the US public limit the calculator's FCC option implements.

Educational information, not medical advice. Every limit quoted here is as published by its dated source; this page paraphrases those sources and adds no health claims of its own. The guidelines are protective documents with their own scope and caveats, and ICNIRP (2010; 2020) carry the full compliance procedures this page only summarises. See About and Methodology for our editorial position.